| Speed Range | 200 rpm – 16,000 rpm |
| Maximum Relative Centrifugal Force | 26,331 x g |
| Maximum Capacity(Rotor) | 4 x 750 ml |
| Refrigeration Range | -4 °F – 104 °F (-20 °C – 40 °C) |
| Program memories | 99 |
| Rotor In Package | Not applicable |
| Acceleration Gear | 10 |
| Deceleration Gear | 10 |
| Dimensions | 26.4 in x 15.4 in x 28.7 in (670 mm x 390 mm x 730 mm) (LxHxW) |
| Display | 2-line, backlit LCD |
| Lid lock | Motor driven |
| Net Weight | 260 lb (118 kg) |
| Noise Level | ≤63±2 dB(A) |
| Power | AC Adapter (Included) |
| Power Consumption | 1,750 W |
| Pre-cool time | From room temperature to 4℃ < 10min |
| Rotor Compatibility | Angle 4 x 85ml RB ID Hi; Angle 12 x 15 ml RB/FA ID; Angle 6 x 250 ml FB ID; Angle 24 x 1.5 / 2.0 ml ID Sealable; Angle 6 x 50 ml RB ID Hi; Swing out 4 x 100 ml ID; Angle 12 x 1.5 / 2.0 ml ID; Angle 4 x 8-w PCR Strip ID; Angle 44 x 1.5 / 2.0 ml ID; Swing out 4x750ml ID Sealable; Swing out 4 x 100 ml ID Sealable; Angle 6 x 85 ml RB ID; Angle 24 x 1.5 / 2.0 ml ID; Rotor Angle 4x500ml ID; Angle 6 x 85 ml RB ID Hi; Angle 30 x 15 ml RB/FA ID; Angle 30 x 1.5 / 2.0 ml ID Sealable; Angle 10 x 50 ml FA ID; Angle 64 x 0.5 ml ID; Angle 20 x 10 ml RB ID Hi; Angle 6 x 50 ml RB/FA ID; Swing out 2 x 3MTP ID |
| Rotor Recognition Method | Auto |
| Running Time | Continous; 10 sec to 99 h 59 min 59 sec; Quickspin |
| Safety Certification | CE; FCC |
| Working Environment | 41°F - 95 °F, 80%RH, non-condensing (5°C – 35°C, 80%RH, non-condensing) |
Original: $12,099.36
-65%$12,099.36
$4,234.78Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Ohaus Centrifuge Multi 120V FC5916R | 83042050
Applications
Display
Operation
Communication
Construction
Design Features
Specifications
| Speed Range | 200 rpm – 16,000 rpm |
| Maximum Relative Centrifugal Force | 26,331 x g |
| Maximum Capacity(Rotor) | 4 x 750 ml |
| Refrigeration Range | -4 °F – 104 °F (-20 °C – 40 °C) |
| Program memories | 99 |
| Rotor In Package | Not applicable |
| Acceleration Gear | 10 |
| Deceleration Gear | 10 |
| Dimensions | 26.4 in x 15.4 in x 28.7 in (670 mm x 390 mm x 730 mm) (LxHxW) |
| Display | 2-line, backlit LCD |
| Lid lock | Motor driven |
| Net Weight | 260 lb (118 kg) |
| Noise Level | ≤63±2 dB(A) |
| Power | AC Adapter (Included) |
| Power Consumption | 1,750 W |
| Pre-cool time | From room temperature to 4℃ < 10min |
| Rotor Compatibility | Angle 4 x 85ml RB ID Hi; Angle 12 x 15 ml RB/FA ID; Angle 6 x 250 ml FB ID; Angle 24 x 1.5 / 2.0 ml ID Sealable; Angle 6 x 50 ml RB ID Hi; Swing out 4 x 100 ml ID; Angle 12 x 1.5 / 2.0 ml ID; Angle 4 x 8-w PCR Strip ID; Angle 44 x 1.5 / 2.0 ml ID; Swing out 4x750ml ID Sealable; Swing out 4 x 100 ml ID Sealable; Angle 6 x 85 ml RB ID; Angle 24 x 1.5 / 2.0 ml ID; Rotor Angle 4x500ml ID; Angle 6 x 85 ml RB ID Hi; Angle 30 x 15 ml RB/FA ID; Angle 30 x 1.5 / 2.0 ml ID Sealable; Angle 10 x 50 ml FA ID; Angle 64 x 0.5 ml ID; Angle 20 x 10 ml RB ID Hi; Angle 6 x 50 ml RB/FA ID; Swing out 2 x 3MTP ID |
| Rotor Recognition Method | Auto |
| Running Time | Continous; 10 sec to 99 h 59 min 59 sec; Quickspin |
| Safety Certification | CE; FCC |
| Working Environment | 41°F - 95 °F, 80%RH, non-condensing (5°C – 35°C, 80%RH, non-condensing) |